中文简体English

TEL 139-0559-1528

LM18-3008

Release time:2020/09/08 Hits:1083 Source:
  • Model Selectable
  • Specifications
  • External diameter
  • Widely used

    英文.jpg

    Instruction of models and parameters LM18-3008 Series
    Model Number(M12 Waterproof Non-buried)
    DC (Direct Current) Type NPN & 3-wire & normal open LM18-3008NA
    NPN & 3-wire & normal close LM18-3008NB
    NPN & 4-wire & one open one close LM18-3008NC
    PNP& 3-wire & normal open LM18-3008PA
    PNP& 3-wire & normal close LM18-3008PB
    PNP & 4-wire & one open one close LM18-3008PC
    2-wire & normal open LM18-3008LA
    2-wire & normal close LM18-3008LB
    AC (Alternating Current) Type 2-wire & normal open LM18-2008A
    2-wire & normal close LM18-2008A
    Detection distance 8mm±10%
    Detection object Metal
    Standard detection object Iron, 48x48x1mm
    Voltage DC type(NPN,PNP,2-wire):10-30VDC
    AC type:90-250VAC
    Static current DC type(NPN,PNP,2-wire):3mA/12V
    5mA/24V,  AC type:
    Response frequency DC type:100Hz,AC type:20Hz
    Output current Resistive load: Max 200mA
    Inductive load: Max 100mA
    Circuit protection DC type  Anti-connection, surge absorption
    Ambient temperature Temperature:-25℃--- +75℃(But not freezing)
    Residual voltage DC Type(NPN,PNP):
    AC Type (2-wire):
    Insulation resistance >50MΩ
    (Shake the meter with DC500V, between the live part and the shell)
    Withstand voltage AC1500V  50/60Hz,1min
    Between the live part and the shell
    Protection level IP67(IEC specifications)


    18A.jpg

    It is widely used in automatic control, quality inspection and safety protection in industries such as bearings, textiles, metallurgy, elevators, and machine tools.

0.239113s