Instruction of models and parameters LJ18A30M-18 Series
Model Number(M12 Waterproof Non-buried)
DC (Direct Current) Type NPN & 3-wire & normal open LJ18A30M-18/Z2CN2/2
NPN & 3-wire & normal close LJ18A30M-18/Z2DN2/2
NPN & 4-wire & one open one close LJ18A30M-18/Z2EN2/2
PNP& 3-wire & normal open LJ18A30M-18/Z2CP2/2
PNP& 3-wire & normal close LJ18A30M-18/Z2DP2/2
PNP & 4-wire & one open one close LJ18A30M-18/Z2EP2/2
2-wire & normal open LJ18A30M-18/Z0AN2/2
2-wire & normal close LJ18A30M-18/Z0BN2/2
AC (Alternating Current) Type 2-wire & normal open LJ18A30M-18/J2A2/2
2-wire & normal close LJ18A30M-18/J2B2/2
Detection distance 18mm±10%
Detection object Metal
Standard detection object Iron, 48x48x1mm
Voltage DC type(NPN,PNP,2-wire):10-30VDC
AC type:90-250VAC
Static current DC type(NPN,PNP,2-wire):3mA/12V
5mA/24V,  AC type:
Response frequency DC type:100Hz,AC type:20Hz
Output current Resistive load: Max 200mA
Inductive load: Max 100mA
Circuit protection DC type  Anti-connection, surge absorption
Ambient temperature Temperature:-25℃--- +75℃(But not freezing)
Residual voltage DC Type(NPN,PNP):
AC Type (2-wire):
Insulation resistance >50MΩ
(Shake the meter with DC500V, between the live part and the shell)
Withstand voltage AC1500V  50/60Hz,1min
Between the live part and the shell
Protection level IP67(IEC specifications)


share: